Tenda OLT initial steps
In this post you'll find step by step instructions for the initial configuration and the IP connectivity of the Tenda TES70 series GPON OLTs: TES7001, TES7002, TES7004, TES7008 and TES7016. After completing these steps, you'll be ready to connect your OLT to SmartOLT.
1Connect to the OLT
Click to choose how you connect to the OLT
- Ethernet / Telnet: a network cable to a factory-new OLT, or the network path of an OLT you can already reach.
- Serial / Console: a console cable to the Console port of the OLT, without any network setup.
Ethernet connection (Telnet)
- On a factory-new OLT, connect an Ethernet cable to:
- TES7001, TES7002: any GE port. These models have no separate management port.
- TES7004, TES7008, TES7016: the NMS port. This is the out-of-band management port and cannot carry customer traffic.
- When you connect directly to the factory IP, configure 192.168.0.1/255.255.255.0 on your PC, or on the MikroTik port connected to the OLT.
- Verify connectivity. You should receive replies.
ping 192.168.0.254ping [OLT IP address]
- Connect with PuTTY or from a terminal, using Telnet. Telnet sends everything, including the password, as plain text. Use it only on a direct cable or a trusted management network. In PuTTY, select Telnet and enter the OLT IP address.
telnet 192.168.0.254telnet [OLT IP address]
- Log in. On a factory-new OLT the username is admin and the password is admin. On an OLT that is already configured, use its existing account.
User Access Verification Username:admin Password: admin>
Serial / Console connection
From a PC (PuTTY)
- Connect a console cable to the RJ45 port labeled Console. The TES7004, TES7008 and TES7016 can also have a USB-C console port.
- If your PC has no serial port, use a USB-to-serial adapter.
- Find the COM port of the adapter in Windows Device Manager (Windows+X), under Ports (COM & LPT).
- In PuTTY, select Serial, enter the COM port and the speed. Set the other values under Connection > Serial:
- Speed: 115200
- Data bits: 8
- Parity: None
- Stop bits: 1
- Flow control: None
- Open the session and press Enter. When the OLT asks for a login, use admin / admin on a factory-new OLT, or the existing account on a configured OLT.
Through a MikroTik
Use the MikroTik serial console port with a compatible cable to the OLT console port. The cable must match the pinout of both serial ports; an RJ45 connector alone does not establish compatibility. Open a MikroTik Terminal through WinBox or SSH over the network.
- Free the serial port, set the OLT console settings, then open the serial session:
/system console disable [find where port=serial0] /port set serial0 baud-rate=115200 data-bits=8 parity=none stop-bits=1 flow-control=none /system serial-terminal serial0
- Press Enter to reach the OLT console.
To close the serial session, press Ctrl+A, release the keys, then press Q.
Enter privileged mode
If the prompt ends with ">", enter enable. The prompt changes to admin#.
admin> enable admin#
2Check the firmware and select the OLT model
admin# show version Software Version: V3.0.1.6
SmartOLT needs firmware V3. On the TES7001 and TES7002, use V3.0.1.1 or newer. If your OLT has older firmware, upgrade it from its web interface first.
If the OLT runs firmware V1, the upgrade does not keep its configuration and you must configure the OLT again.
Select your OLT model
3Configure a new management IP address
Select the interface of the management IP
From the factory, all the uplink ports carry the management VLAN 4088 untagged. Connect any of them to your router.
admin# configure terminal admin(config)# interface vlan 4088 admin(config-vlan4088)# manage ip address 10.200.0.2 255.255.255.0 admin(config-vlan4088)# end admin#
If you connected over Ethernet using the old IP address, reconnect on the new IP address 10.200.0.2 and enter enable again.
Check which default route the OLT has now:
admin# show ip route admin#
The line that starts with 0.0.0.0 is the current default route. The next command replaces it with your gateway.
Set the default gateway and save the configuration:Make sure the default gateway IP address 10.200.0.1 is already configured on your router.
admin# configure terminal
admin(config)# manage ip-gateway static 10.200.0.1
admin(config)# end
admin# write
Generating configuration file...
Done
admin#
Check again. The 0.0.0.0 line must show your gateway:
admin# show ip route Destination Gateway Genmask Flags Metric Ref Use Interface 0.0.0.0 10.200.0.1 0.0.0.0 UG 0 0 0 vlanif4088 admin#
Ping the gateway from the OLT to confirm the route works. You should receive replies.
admin# ping 10.200.0.1
admin#
4Set the username/password for SmartOLT
This user/pass will be used by SmartOLT to connect to your OLT. You can use the admin user of the OLT. First change its factory password:
admin# configure terminal admin(config)# username admin password (insert a strong password here) admin(config)# end admin# write admin#
If you want a dedicated user for SmartOLT, add it as follows. The type operational gives it the same provisioning rights as the admin user.
The password has 8 to 32 characters, with at least two of these: letters, digits, symbols. Do not use spaces or "?".
Enter a valid password above, or click Generate, to generate the commands.
At this stage, your OLT is ready to be interconnected with SmartOLT.
Open your SmartOLT site, go to Settings → OLTs → Add OLT, select Tenda and Telnet, fill in the fields displayed, click Test connection, and then Save.
# Other general settings (If you use SmartOLT, these are configured automatically, no need to configure them manually):
admin# configure terminal admin(config)# snmp-server admin(config)# snmp-server community [READ COMMUNITY] view Default ro admin(config)# snmp-server community [WRITE COMMUNITY] view Default rw admin(config)# save period 1 admin(config)# clock timezone utc [OFFSET] admin(config)# time set [YEAR] [MONTH] [DAY] [HH:MM:SS]