C-Data OLT initial steps
In this post you'll find step by step instructions for the initial configuration and the IP connectivity of the C-Data FD1600 and FD1700 series GPON OLTs, such as the FD1601S, FD1602S, FD1604, FD1608, FD1616S and FD1708S to FD1732S. After completing these steps, you'll be ready to connect your OLT to SmartOLT.
1Connect to the OLT
Click to choose how you connect to the OLT
- Ethernet / Telnet: a network cable to the MGMT port of a factory-new OLT, or the network path of an OLT you can already reach.
- Serial / Console: a console cable to the CONSOLE port of the OLT, without any network setup. Use it on a factory-new FD1601S or FD1602S, which have no MGMT port.
Ethernet connection (Telnet)
- On a factory-new OLT, connect an Ethernet cable to the MGMT port. This is the out-of-band management port and cannot carry customer traffic. The FD1601S and FD1602S have no MGMT port: use the serial connection. If the OLT is already reachable over your network, keep the existing cabling.
- When you connect directly to the factory IP, configure 192.168.1.1/255.255.255.0 on your PC, or on the MikroTik port connected to the OLT.
- Verify connectivity. You should receive replies.
ping 192.168.1.100ping [OLT IP address]
- Connect with PuTTY or from a terminal, using Telnet. Telnet sends everything, including the password, as plain text. Use it only on a direct cable or a trusted management network. In PuTTY, select Telnet and enter the OLT IP address.
telnet 192.168.1.100telnet [OLT IP address]
- Log in. On a factory-new OLT the username is root and the password is admin. On an OLT that is already configured, use its existing account.
User Access Verification User name: root Password: admin OLT>
Serial / Console connection
From a PC (PuTTY)
- Connect a console cable to the RJ45 port labeled CONSOLE.
- If your PC has no serial port, use a USB-to-serial adapter.
- Find the COM port of the adapter in Windows Device Manager (Windows+X), under Ports (COM & LPT).
- In PuTTY, select Serial, enter the COM port and the speed. Set the other values under Connection > Serial:
- Speed: 115200
- Data bits: 8
- Parity: None
- Stop bits: 1
- Flow control: None
- Open the session and press Enter. When the OLT asks for a login, use root / admin on a factory-new OLT, or the existing account on a configured OLT.
Through a MikroTik
Use the MikroTik serial console port with a compatible cable to the OLT console port. The cable must match the pinout of both serial ports; an RJ45 connector alone does not establish compatibility. Open a MikroTik Terminal through WinBox or SSH over the network.
- Free the serial port, set the OLT console settings, then open the serial session:
/system console disable [find where port=serial0] /port set serial0 baud-rate=115200 data-bits=8 parity=none stop-bits=1 flow-control=none /system serial-terminal serial0
- Press Enter to reach the OLT console.
To close the serial session, press Ctrl+A, release the keys, then press Q.
Enter privileged mode
If the prompt ends with ">", enter enable. The prompt changes to "#". Before it, the OLT shows its own name, for example FD1608E-C1#. This guide shows OLT#.
OLT> enable OLT#
2Check the firmware and select the OLT model
OLT# show version ... Hardware version : V1.1 Firmware version : V3.4.14_250616
SmartOLT needs firmware V3. If your OLT has an older version, ask your C-Data supplier for an upgrade.
Select your OLT model
3Configure a new management IP address
Select the interface of the management IP
Connect the MGMT port to your router. This port is for management purposes only and cannot carry customer traffic.
OLT# config OLT(config)# interface mgmt OLT(config-interface-mgmt)# ip address 10.200.0.2 255.255.255.0 OLT(config-interface-mgmt)# end OLT#
If you connected over Ethernet using the old IP address, reconnect on the new IP address 10.200.0.2 and enter enable again.
Check the IP addresses of the OLT. Each interface must have its own subnet. From the factory, the interface Mgmt 0/0 has the IP address 192.168.1.100/24, also on the models without a MGMT port.
OLT# show ip interface brief OLT#Set the default gateway and save the configuration. The new gateway replaces the default gateway that the OLT has now:
Make sure the default gateway IP address 10.200.0.1 is already configured on your router.
OLT# config
OLT(config)# ip route-default gateway 10.200.0.1
OLT(config)# save
OLT(config)# end
OLT#
Check the default gateway:
OLT# show current-config include gateway
default gateway 10.200.0.1
OLT#
If the command shows nothing, use show current-config include route.
Ping the gateway from the OLT. You should receive replies.
OLT# ping 10.200.0.1
OLT#
4Create a dedicated username/password
This user/pass will be used by SmartOLT to connect to your OLT. SmartOLT does not accept the root user, so create a dedicated one. The privilege level 15 gives it the same rights as root.
The password has 8 to 16 characters, with at least two of these: letters, digits, symbols. Do not use spaces or "?".
Enter a valid password above, or click Generate, to generate the commands.
Check that Telnet is enabled on the OLT:
OLT# show service status SERVICE PORT DEFAULT PORT STATUS telnet 23 23 enable OLT#
If the telnet line shows disable, enable it:
OLT# config OLT(config)# service telnet enable OLT(config)# save OLT(config)# end OLT#
At this stage, your OLT is ready to be interconnected with SmartOLT.
Open your SmartOLT site, go to Settings → OLTs → Add OLT, select C-Data, your OLT model and Telnet, fill in the fields displayed and click Save. SmartOLT adds the OLT and configures SNMP on it.
# Other general settings (If you use SmartOLT, these are configured automatically, no need to configure them manually):
OLT# config OLT(config)# snmp-agent community read [READ COMMUNITY] OLT(config)# snmp-agent community write [WRITE COMMUNITY] OLT(config)# service snmp enable OLT(config)# timezone gmt+ [HH:MM] OLT(config)# time [YYYY/MM/DD-HH:MM:SS]